PRODUCT DESCRIPTION
KEYENCE CORP FD-HCC10 - Digital Clamp-on Liquid Flow Sensor
This device is a non-invasive, high-accuracy digital flow sensor from the KEYENCE FD-H series, engineered for precise liquid flow measurement in industrial pipelines. Utilizing transit-time ultrasonic technology, it provides real-time flow rate data without requiring pipe modification. It integrates directly into process control systems for monitoring, control, and consumption management applications.
Technical Specifications:
- SERIES/FAMILY: FD-H Series
- COMPONENT TYPE: Digital Clamp-on Liquid Flow Sensor
- ELECTRICAL SPECS:
- POWER SUPPLY: 24 VDC +/-10%
- CURRENT CONSUMPTION: 150 mA (max)
- DIGITAL OUTPUTS: 2x NPN/PNP selectable, 30 VDC, 50 mA (max)
- ANALOG OUTPUT: 4-20 mA (load resistance 250 Ohm max)
- PULSE OUTPUT: Open collector, 30 VDC, 50 mA (max)
- MECHANICAL/PHYSICAL:
- MEASUREMENT PRINCIPLE: Transit-time ultrasonic
- COMPATIBLE PIPE OUTER DIAMETER: 13.8 mm to 34.0 mm (0.54 to 1.34)
- COMPATIBLE PIPE MATERIALS: Stainless steel, iron, copper, PVC, PVDF, etc. (sound-transmitting materials)
- MEASURABLE FLUIDS: Water, deionized water, oils, chemicals (fluids with sound transmission properties)
- FLOW RATE RANGE: 0 to 100 L/min (dependent on pipe diameter and fluid properties)
- DISPLAY: 4-digit 7-segment LED, 2-color (red/green)
- INTERFACE/CONTROL:
- COMMUNICATION: Standard industrial analog, digital, and pulse outputs
- FEEDBACK: Real-time flow rate, totalized flow, error status
- PROGRAMMING: On-device push-button configuration
- ENVIRONMENTAL/MOUNTING:
- IP RATING: IP65/IP67 (sensor head), IP65 (main unit)
- OPERATING TEMPERATURE: -10 to +60 degrees C (14 to 140 degrees F)
- MOUNTING STYLE: Clamp-on (non-invasive)
- HOUSING MATERIAL: PBT, SUS304, PPS
- COMPATIBILITY/APPLICATION:
- TARGET SYSTEMS: Process control systems, SCADA, PLCs, data acquisition systems
- APPLICATIONS: Liquid flow monitoring, consumption management, batch control, leak detection, cooling water management, chemical dosing, HVAC systems