PRODUCT DESCRIPTION
SIEMENS 7ME6110-1HA20-2AA4 - Electromagnetic Flowmeter
The SIEMENS 7ME6110-1HA20-2AA4 is an integrated electromagnetic flowmeter from the SITRANS F M MAG 5100W series, engineered for precise volumetric flow measurement of conductive liquids in industrial water and wastewater applications. This device combines a robust flanged sensor with a high-performance MAG 6000 transmitter, providing accurate data acquisition and PROFIBUS PA communication for seamless integration into process control systems. It is designed for demanding environments requiring reliable flow monitoring and control.
Technical Specifications:
- SERIES/FAMILY: SITRANS F M MAG 5100W (Sensor) / MAG 6000 (Transmitter)
- COMPONENT TYPE: Electromagnetic Flowmeter
- ELECTRICAL SPECS:
- POWER SUPPLY: 100-230VAC, Single Phase, 50/60Hz
- POWER CONSUMPTION: Max. 15W
- ANALOG OUTPUT: 0/4-20mA (active/passive)
- PULSE OUTPUT: Scalable, passive
- RELAY OUTPUT: Configurable (e.g., alarm, direction)
- MECHANICAL/PHYSICAL:
- NOMINAL DIAMETER: DN 100 (4 inch)
- LINER MATERIAL: EPDM (Ethylene Propylene Diene Monomer)
- ELECTRODE MATERIAL: Hastelloy C
- PRESSURE RATING: PN 16 (16 bar)
- PROCESS TEMPERATURE: -10 to +70 degrees C
- FLANGE STANDARD: EN 1092-1 (PN 16)
- INTERFACE/CONTROL:
- COMMUNICATION PROTOCOL: PROFIBUS PA
- DIGITAL INPUT: 1x (configurable)
- DISPLAY: Alphanumeric, backlit LCD
- ENVIRONMENTAL/MOUNTING:
- IP RATING: IP67 (Sensor and Transmitter)
- COOLING METHOD: Natural Convection
- MOUNTING STYLE: Compact (sensor and transmitter integrated)
- AMBIENT TEMPERATURE: -20 to +60 degrees C (for transmitter)
- COMPATIBILITY/APPLICATION:
- MEASUREMENT MEDIUM: Conductive liquids (water, wastewater, slurries)
- TARGET APPLICATIONS: Water treatment, sewage plants, irrigation, industrial process water management.
- SYSTEM INTEGRATION: DCS, PLC, SCADA systems via PROFIBUS PA.