PRODUCT DESCRIPTION
SIEMENS 7ME6140-1VA10-1AA1 - Electromagnetic Flowmeter
This is an electromagnetic flowmeter system comprising a SIEMENS SITRANS F M MAG 5100W sensor and a SITRANS F M MAG 5000 transmitter, engineered for precise volumetric flow measurement of conductive liquids in water and wastewater applications. The robust design, featuring an EPDM liner and Hastelloy C-22 electrodes, ensures reliable operation in challenging industrial environments, providing critical data for process control and monitoring.
Technical Specifications:
- SERIES/FAMILY: SITRANS F M MAG 5100W (Sensor), SITRANS F M MAG 5000 (Transmitter)
- COMPONENT TYPE: Electromagnetic Flowmeter
- ELECTRICAL SPECS:
- POWER SUPPLY: 100-230VAC, 50/60 Hz
- POWER CONSUMPTION: Approximately 15 VA
- MECHANICAL/PHYSICAL:
- NOMINAL DIAMETER: DN40 (40 mm)
- LINER MATERIAL: EPDM (Ethylene Propylene Diene Monomer)
- ELECTRODE MATERIAL: Hastelloy C-22
- FLANGE MATERIAL: Carbon Steel, ASTM A105, with corrosion protection
- PROCESS CONNECTION: Flanged, ANSI Class 150, EN 1092-1 PN16, AS 2129 Table E
- MEASUREMENT PRINCIPLE: Electromagnetic Induction
- MEASUREMENT RANGE: 0 to 10 m/s
- ACCURACY: +/- 0.2% of flow rate
- INTERFACE/CONTROL:
- OUTPUTS: 0/4-20 mA Current Output, Pulse/Frequency Output, Status Output
- INPUTS: Digital Input
- COMMUNICATION PROTOCOLS: HART (Standard)
- DISPLAY: Alphanumeric LCD
- ENVIRONMENTAL/MOUNTING:
- IP RATING: IP67 (Sensor and Transmitter)
- AMBIENT TEMPERATURE: -20 to +60 °C (Transmitter), -20 to +70 °C (Sensor)
- MEDIUM TEMPERATURE: -10 to +70 °C (with EPDM liner)
- MOUNTING STYLE: Inline, Flanged
- CABLE GLANDS: M20 x 1.5
- COMPATIBILITY/APPLICATION:
- TARGET APPLICATIONS: Water treatment, wastewater management, sewage, sludge, process water, cooling water, chemical dosing.
- MEDIA COMPATIBILITY: Conductive liquids (minimum 5 µS/cm conductivity).